Dolby Laboratories DM100 Manual do Utilizador Página 25

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 36
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 24
Dolby Model DP583 Frame Synchronizer User’s Manual Applications
3-5
DP583 Primary Unit
Synchronization
Processing
Main
Input
Bypass Input
Main
Output
Synchronization
Processing
Main
Input
Bypass Input
Main
Output
DP583 Standby Unit
Audio
Input
Audio
Output
Figure 3-5 Hot-Standby Operation of the DP583
The unit automatically enters Bypass mode when an internal fault occurs or when
power to one unit is lost. Bypass mode can also be selected from the I/O Control
menu or via the GPI/O input port.
For further security, pins 5 and 9 (ground) of the GPI/O ports can be used to control a
unit fault alert. If pin 5 goes “low,” then a hardware fault has occurred. These can be
used on both units so that a faulty standby DP583 can be identified before it is
required. Pins 2, 3, 4, and 8 can also be used to ascertain whether the unit is
producing an invalid output, and to trigger a warning.
MAIN
Vista de página 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 35 36

Comentários a estes Manuais

Sem comentários