DM100 User’s Manual Operation: Status Mode
3-30
3.2.8 Error Stats Menu
After pressing [Enter] to select the Error Statistics menu, press
the [Down] or [Up] button to select the desired error screen. A
typical example screen is shown.
The first screen displays any current error condition that
prevents correct operation of the DM100. Subsequent screens
display a historical count of errors. Error counts over 99 display
as 99. Press [Enter] to reset a displayed error count to 00.
Error Stats
ENTER to view
Error Cond
No Error
Error Cond
[Down]
Dolby E Errors
CRC:xx
[Down]
Dolby D Errors
CRC:xx
[Down]
Pa Alignment
ERR:xx
When receiving a
bitstream, this screen
shows the number of
frames where the SMPTE-
337M Pa word does not
appear in the Left channel.
[Down]
Parity, Code,
Confidence
AES3 Errors 1
P:aa CD:bb CF:cc
[Down]
Professional
AES3 Errors 2
Channel Status CRC
CCRC:dd
No Error
The channel mode in Dolby E
input is invalid.
Invalid Ch Mode
Selected Dolby E program does
not exist.
Invalid Program
Selected Decode Format not
present in input.
Invalid Format
Selected AES Channel does not
contain a valid Dolby Digital
stream.
Invalid AES Ch
Selected Stream # is not present
or does not contain a valid
Dolby Digital stream.
Invalid Stream #
Selected Output Channel (for
speaker/headphones) is not
present in the input signal.
Invld Output Ch
Selected generator clock source
is missing or bad, or in I/O
Drift mode, the video input is
missing or not at 29.97 or 25
fps.
Invalid Gen Clk
The input is not set to
Autodetect and the selected
input has no valid AES signal
or there is no input when in
A/V Freq Drift or Latency Test
modes.
No Input